No-Flow Temperature


Test ID  
R-018

   
Description  
This test determines the approximate no flow temperature of a material. The barrel of the rheometer is heated to the lowest processing temperature of the material. The material is loaded into the barrel and given a six-minute hold time, to ensure the material is completely molten. The material is allowed to cool slowly. A pressure is periodically applied to check for flow of material. The no flow temperature is achieved when the flow rate is less than 2mm/min at a pressure of 130 bar.    
Data see sample data  
A no-flow temperature is reported. This data appears in Matereality as No-Flow Temperature.  
Replicates (# of times this test is repeated)  
1  
Samples  
0.3 - kg of pellets [details]

   

Application
 
The data reported is useful for injection molding simulatons.