No-Flow Temperature


Test ID

R-018

Description

This test determines the approximate no flow temperature of a material. The barrel of the rheometer is heated to the lowest processing temperature of the material. The material is loaded into the barrel and given a six-minute hold time, to ensure the material is completely molten. The material is allowed to cool slowly. A pressure is periodically applied to check for flow of material. The no flow temperature is achieved when the flow rate is less than 2mm/min at a pressure of 130 bar.

Options

Standards

  • DPL R-018N

Data

No-Flow Temperature. This data appears in Matereality as No-Flow Temperature.

Replicates

Number of times this test is repeated: 1

Samples

0.3 kg of pellets [details]

Application

The data reported is useful for injection molding simulatons.