No-Flow Temperature
Test ID
R-018
Description
This test determines the approximate no flow temperature of a material. The barrel of the rheometer is heated to the lowest processing temperature of the material. The material is loaded into the barrel and given a six-minute hold time, to ensure the material is completely molten. The material is allowed to cool slowly. A pressure is periodically applied to check for flow of material. The no flow temperature is achieved when the flow rate is less than 2mm/min at a pressure of 130 bar.
Options
Standards
- DPL R-018N
Data
No-Flow Temperature. This data appears in Matereality as No-Flow Temperature.
Replicates
Number of times this test is repeated: 1
Samples
0.3 kg of pellets [details]
Application
The data reported is useful for injection molding simulatons.