SIGMASOFT Mechanical Test
Test ID
M-101T
Description
Modulus and Poisson's ratio tests are performed at five temperatures with only one replicate being performed at each temperature.
Options
Standards
- ASTM D638
- ISO 527-1
Data
Engineering Tensile Stress-Strain Curves, Poissons Ratio, Tensile Modulus. This data appears in Matereality as Tensile Properties.
Replicates
Number of times this test is repeated: 1
Samples
5 plaques (4 x 12in) [details]
Application
Only intended for use in injection molding softwares in which temperature dependent modulus and Poisson's ratio data is required.