Charpy Pendulum Impact


Test ID

M-427

Description

A Dynatup POE 2000 apparatus is used to impact a specimen.  Specimens are bars with dimensions specified in ASTM and notched accordingly.  Sample is placed horizontally, with notch opposite of impact side.  At set velocity and energy, pendulum is released to impact specimen.  Test is complete when pendulum completes one swing.  Five replicates are performed.

Options

Standards

  • ASTM D6110
  • ISO 179

Data

Break Type, Impact Strength. This data appears in Matereality as Charpy Impact.

Replicates

Number of times this test is repeated: 5

Samples

10 notched Charpy specimens [details]

Application

This test is used as a means of quality control or materials specification. It can, in some cases, be used on a finished product to determine if the part will fracture under the set conditions. Data gathered from this test are valuable for comparative purposes, to aid the engineer in choosing an appropriate material for a specific application.