Heat Transfer Coefficient


Test ID

T-150

Description

This test measures the interfacial conductivity of a material using a guarded heat flow meter. A sample measuring 2" in diameter is placed between the upper and lower plates of a guarded heat flow meter. A thin layer of conductive grease is applied to the top and bottom of the sample and it is clamped in place. The upper and lower plates are controlled at different temperatures, thus inducing heat flow through the sample. A heated guard surrounding the sample reduces the lateral heat flow. From the measure of heat flow, thermal conductivity is calculated. The test is repeated with the conductive grease on one side only and the additional effect due to the interfacial heat transfer coefficient is measured. From the data that is collected, the heat transfer coefficient is calculated.

Options

Standards

  • ASTM E1530

Data

Thermal Resistance v. Temperature. This data appears in Matereality as Thermal Conductivity.

Replicates

Number of times this test is repeated: 1

Samples

1 plaques [details]

Application

This test is useful when looking at the effects of various greases, lubricants, and coating materials on heat transfer properties.