Flexural Modulus vs. Temperature by DMA


Test ID

M-604

Description

The test specimen in the form of a rectangular bar is subjected to 3 oscillatory point bending at constant frequency and small dynamic strain while being heated at a constant rate. A preload is applied to ensure the test specimen is always in contact with the loading nose.

Options

Standards

  • ASTM D5023
  • ASTM D7028

Data

Flexural Modulus v. Temperature, Tan Delta v. Temperature. This data appears in Matereality as Dynamic Mechanical Properties in Flexure.

Replicates

Number of times this test is repeated: 1

Samples

2 flex bars [details]

Application

Flexural properties are especially useful for quality control and specification purposes.