Flexural Modulus vs. Temperature by DMA
Test ID
M-604
Description
The test specimen in the form of a rectangular bar is subjected to 3 oscillatory point bending at constant frequency and small dynamic strain while being heated at a constant rate. A preload is applied to ensure the test specimen is always in contact with the loading nose.
Options
Standards
- ASTM D5023
- ASTM D7028
Data
Flexural Modulus v. Temperature, Tan Delta v. Temperature. This data appears in Matereality as Dynamic Mechanical Properties in Flexure.
Replicates
Number of times this test is repeated: 1
Samples
2 flex bars [details]
Application
Flexural properties are especially useful for quality control and specification purposes.