Flexural Fatigue S-N Curves
Test ID
M-504
Description
The fatigue test is performed at 4 stresses to cover 4 decades of failure, from 1,000 through 1,000,000 cycles, in order to generate an S-N curve. Please call for more details.
NOTE: Due to the long-term nature of this test it is necessary to speak to a sales associate before placing an order. Because the typical test duration is 2 weeks, priority and economy pricing are not available unless a shorter test duration is desired.
Options
This test can be run at non-ambient temperatures for an additional cost.
Standards
- ASTM D671
Data
Cycles to Failure. This data appears in Matereality as Flexural Fatigue.
Replicates
Number of times this test is repeated: 3
Samples
50 flex fatigue specimens [details]
Application
S-N curves provide a measure of the fatigue life of materials. Care should be taken in extrapolation of this data.