SIGMASOFT Shrinkage Option for unfilled materials


Test ID

U-064 UF

Description

This Option must be ordered with U-060 or U-061 TestPaks. Tests are added to include Bagley correction of capillary viscosity data. PVT is measured in isobaric mode. Mechanical properties for shrinkage are also added. For use in unfilled materials and materials to be considered isotropic.

Included Tests

1x M-101T SIGMASOFT Mechanical Test
1x D-021 PVT (Isobaric)
3x R-012 Capillary Rheology with Bagley Correction (1 Temperature)

Options

Samples

: 6 tensile bars

[details]

Application

Add support for shrinkage simulations with SIGMASOFT. This conforms with 2018 guidance from SIGMASOFT.