VISI Flow Filling


Test ID

G-220

Description

Properties needed to perform a VISI Flow injection mold-filling and cooling simulation are generated. These include viscosity vs. shear rate at three temperatures (two in the processing range and one below); melt thermal conductivity, specific heat and latent heat if applicable, melt and solid density, a no-flow temperature, and an eject temperature. Thermal diffusivity is calculated.

Included Tests

1x D-010 Solid Density
1x D-015 Melt Density
3x R-011 Capillary Rheology (1 Temperature)
1x T-101 Thermal Conductivity (Melt)
1x T-012 Transition and Eject Temperature
1x T-015 Specific Heat

Options

Samples

: 1 kg of pellets

[details]

Application

According to VISI Flow, this module allows the user to optimize the filling and holding conditions (time, temperature, pressure, etc.), minimize the dimensions of the sprue and cold runners, simulate hot and insulated runners, compute clamping force and its evolution during the filling.